Würth UAE Contact +971 50 858 2034 | Free delivery on orders above 200 AED

Fixanchor W-FA/A4

Fixanchor W-FA A4 stainless steel
ANC-(W-FA)-A4/70-10-M8X75

Art.-no. 0904411083
EAN 4045727378182

Prices for customers after login

Exclusively for trade customers

Register now and access more than 125,000 products

Fixanchors for standard applications in uncracked concrete and anchors in a redundant non-structural system in cracked concrete (size M6). A4 stainless steel
  • Very flexible application thanks to three effective anchorage depths

  • Small spacings and edge distances

  • Time-saving push-through installation
Proof of Performance
  • European Technical Assessment ETA-02/0001 for individual fixing point, option 7, uncracked concrete: Static or quasi-static action (M6-M20)

  • European Technical Assessment ETA-06/0162 for anchors in a redundant non-structural system in non-load-bearing systems, cracked and uncracked concrete, size M6

  • Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC - uniform temperature time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-06/0162, size M6 only)
Application area
Heavy steel structures
Fence systems
Post support bracket
Drill the hole
Clean the drill hole
Knock in anchor with mason's mallet or machine setting tool
Apply torque
  • European Technical Assessment ETA-02/0001 for individual fixing point, option 7, uncracked concrete: Static or quasi-static action (M6-M20)

  • European Technical Assessment ETA-06/0162 for anchors in a redundant non-structural system in non-load-bearing systems, cracked and uncracked concrete, size M6

  • Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC - uniform temperature time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-06/0162, size M6 only)
Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Application area
  • Individual fixing point or anchors in a redundant non-structural system with European Technical Approval in normal weight concrete C20/25 to C50/60 (uncracked concrete only)

  • Anchors in a redundant non-structural system in non-load-bearing systems in concrete (size M6, cracked and uncracked concrete)

  • For use in concrete < C20/25 and pressure-resistant natural stone (without approval/assessment)

  • Fastenings under exposure to fire (size M6 only)

  • Suitable for anchoring medium to heavy loads in concrete: Mounting of e.g. metal structures, metal profiles, brackets, base plates, cable conduits, pipes, wooden structures, beams, purlins, fences etc.

  • W-FA/A4 (A4 stainless steel) is suitable for use in dry indoor areas or wet rooms and for use outdoors (including in industrial atmospheres and close to the sea), provided that no particularly aggressive conditions are present

Metric anchor diameter

M8

Anchor length (l)

75 mm

Material

Stainless steel A4

Attachment height (t fix)

10 mm

Max. attachment height reduced (t fix, red)

19 mm

Attachment height (t fix 2)

19 mm

Drill hole depth (h 1)

65 mm

Drill hole depth reduced (h 1, red)

55 mm

Drill hole depth (h 1.2)

55 mm

Effective anchoring depth (h ef)

44 mm

Effective anchoring depth reduced (h ef, red)

35 mm

Effective anchoring depth (h ef 2)

35 mm

Embedding depth (h nom)

56 mm

Embedding depth (h nom,red)

47 mm

Width across flats

13 mm

Nominal drill-bit diameter (d 0)

8 mm

Through-hole in the component to be connected (d f)

9 mm

Thread length (L th)

40 mm

Approval

ETA-02/0001

Performance data
Anchor diameter [mm]M6M8M10M12M16M20
F60 [kN]0,5-0,8-1,2-1,8-3,4-5,25-
F90 [kN]0,3-0,5-0,8-1,2-2,2-3,6-
F120 [kN]0,25-0,4-0,6-0,9-1,7-2,75-
Standard effective anchorage depth/reduced effective anchorage depthhef/hef red [mm]4030443548426550826410078
Admissible centric tension load1) on an individual anchor without the influence of the edge distanceCompressive zone (uncracked concrete) C20/252),
s ≥ 3 hef, c ≥ 1.5 hef)
Nadm [kN] =
C20/252)
4,12,95,75,07,66,512,68,517,812,32416,5
Admissible shear load1) on an individual anchor without the influence of the edge distanceCompressive zone
(uncracked concrete C20/252), c ≥ 10 hef)
Vadm [kN] =
C20/252)
2,92,96,35,08,06,514,38,523,623,637,133,1
Admissible bending momentMadm [Nm]5,15,113,113,125,725,744,644,699,999,9195195
Fire resistance rating (W-FA/S)F30 [kN]0,9-1,4-2,2-3,2-6,0-10,0-
Characteristic values
Embedment depthhnom/hnom,red [mm]4939564762568166998312199
Nominal drill dia.d0 [mm]66881010121216162020
∅ of cutting edgesdcut ≤ [mm]6,46,48,458,4510,4510,4512,512,516,516,520,5520,55
Drill hole depthh1/h1,red ≥ [mm]554565557065907511095130110
Through hole in the component being connecteddf ≤ [mm]77991212141418182222
Individual fixing point
Minimum member thicknesshmin [mm]1008010080100100130100160130200160
Uncracked concrete, option 7 (A4/HCR stainless steel - M6 to M20: ETA-02/0001)
Torque while installing anchorTinst = [Nm]66151525255050100100160160
Spacingscr,N [mm]12090132105144126195150240192300234
Edge distanceccr,N [mm]604566537263987512096150117
Minimum spacingsmin [mm]3535356045556010080110100140
Minimum spacingfor c ≥ [mm]40-65-70-100-120-150-
Minimum edge distancecmin [mm]3540456055657010080110100140
Minimum edge distancefor s ≥ [mm]60-110-80-100-140-180-

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information